© 2003 by BMJ Publishing Group Ltd & British Society of Gastroenterology
STOMACH
Fundic accommodation assessed by SPECT scanning: comparison with the gastric barostat
1 Departments of Gastroenterology and Hepatology, Academic Medical Centre, Amsterdam, the Netherlands
2 Department of Nuclear Medicine, Academic Medical Centre, Amsterdam, the Netherlands
Correspondence to:
Correspondence to:
Dr G E Boeckxstaens
Department of Gastroenterology and Hepatology, Academic Medical Centre, Room C2-211, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands; g.e.boeckxstaens{at}amc.uva.nl
Background: Recently, single photon emission computed tomography (SPECT) scanning was described as a non-invasive technique to assess fundic accommodation. However, in contrast with the barostat, no intragastric distending force is applied during SPECT scanning. We hypothesised that in the absence of a barostat balloon, SPECT scanning largely detects the volume effect of the ingested meal and is a rather insensitive tool to detect fundic relaxation.
Methods: After an overnight fast, healthy volunteers underwent a barostat study and SPECT scanning on two separate days to assess: (1) meal induced fundic accommodation (Nutridrink, 200 ml, 300 kcal); and (2) gastric relaxation to 1 mg intravenous glucagon.
Results: Fasting fundic volumes (145 (8) v 280 (32) ml; p=0.001) and average postprandial volume (329 (10) v 571 (53) ml; p=0.001) were significantly lower measured with SPECT compared with the barostat study. Meal induced fundic relaxation (183 (10) v 289 (46) ml; p=0.050) and the postprandial/fasting volume ratio (2.32 (0.10) v 2.27 (0.29); p=0.892) did not differ significantly between SPECT scanning and the barostat. However, no correlation could be determined between accommodation volumes measured by both techniques. In contrast with meal induced relaxation, the glucagon induced increase in fundic volume (19 (5) v 406 (56) ml; p=0.007) and post/pre glucagon ratio (1.16 (0.03) v 3.02 (0.54); p=0.046) were significantly lower when measured by SPECT scanning compared with the barostat.
Conclusion: SPECT scanning detects changes in postprandial volume but is less suitable than the gastric barostat in detecting changes in gastric tone. Our study therefore questions its role as a tool to detect impaired accommodation and warrants further validation of this technique.
Keywords: Barostat; dyspepsia; gastric accommodation; single photon emission computed tomography
Abbreviations: SPECT, single photon emission computed tomography; MDP, minimal distending pressure; VAS, visual analogue scale; FD, functional dyspepsia
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Goetze, O., Steingoetter, A., Menne, D., van der Voort, I. R., Kwiatek, M. A., Boesiger, P., Weishaupt, D., Thumshirn, M., Fried, M., Schwizer, W.
(2007). The effect of macronutrients on gastric volume responses and gastric emptying in humans: a magnetic resonance imaging study. Am. J. Physiol. Gastrointest. Liver Physiol.
292: G11-G17
[Abstract] [Full Text] -
de Zwart, I. M., Haans, J. J. L., Verbeek, P., Eilers, P. H. C., de Roos, A., Masclee, A. A. M.
(2007). Gastric accommodation and motility are influenced by the barostat device: assessment with magnetic resonance imaging. Am. J. Physiol. Gastrointest. Liver Physiol.
292: G208-G214
[Abstract] [Full Text] -
Mundt, M W, Samsom, M
(2006). Fundal dysaccommodation in functional dyspepsia: head-to-head comparison between the barostat and three-dimensional ultrasonographic technique. Gut
55: 1725-1730
[Abstract] [Full Text] -
Kindt, S, Tack, J
(2006). Impaired gastric accommodation and its role in dyspepsia. Gut
55: 1685-1691
[Abstract] [Full Text] -
Burton, D. D., Kim, H. J., Camilleri, M., Stephens, D. A., Mullan, B. P., O'Connor, M. K., Talley, N. J.
(2005). Relationship of gastric emptying and volume changes after a solid meal in humans. Am. J. Physiol. Gastrointest. Liver Physiol.
289: G261-G266
[Abstract] [Full Text] -
Bennink, R. J., van den Elzen, B. D., Kuiken, S. D., Boeckxstaens, G. E.
(2004). Noninvasive Measurement of Gastric Accommodation by Means of Pertechnetate SPECT: Limiting Radiation Dose Without Losing Image Quality. JNM
45: 147-152
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.