Gut 2005;54:1682-1686
OESOPHAGUS
Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo)
1 Institut des Maladies de lAppareil Digestif, CHU- Hôtel Dieu, Nantes, France
2 Fédérations des Spécialités Digestives, Hospices Civils, Lyon, France
3 Policlinique Hôpital Charles Nicolle, Rouen, France
4 Service des Maladies de lAppareil Digestif, Bordeaux, France
5 Physiologie Digestive et Urinaire, Hôpital Charles Nicolle, Rouen, France
Correspondence to:
Dr S Bruley des Varannes
Department of Gastroenterology and Hepatology, Hôpital Hôtel Dieu, 44093 Nantes cedex, France; bruley{at}easynet.fr
Objectives: Oesophageal pH monitoring is a useful test for the diagnosis of gastro-oesophageal reflux disease (GORD) but has some limitations related to the nasopharyngeal electrode. Recently, a telemetric catheter free system (CFS) (Bravo; Medtronic) was developed. The aim of this study was to determine the concordance of data between the conventional pH measurement system (CPHMS) and the CFS Bravo.
Methods: Forty patients with symptoms suggestive of GORD underwent 24 hour oesophageal pH monitoring using the CPHMS with a nasopharyngeal electrode and the Bravo CFS simultaneously. The sensitive tips of both electrodes were positioned at the same level under fluoroscopy. In addition to automatic analysis, each reflux episode was checked visually and characterised.
Results: There was a significant correlation (r = 0.87, p<0.0001) between the 24 hour oesophageal acid exposures recorded by the CPHMS and the CFS. Twenty four hour oesophageal acid exposure was significantly lower with the CFS than with the CPHMS (2.4 (0.48.7) v 3.6 (0.78.6); p< 0.0001). Consequently, with the CFS, the cut off level for the diagnosis of GORD, as calculated from the regression equation, was 2.9% (for the 4.2% cut off determined in controls with the CPHMS). After this adjustment, concordance of the diagnosis of GORD was 88% (kappa 0.760). Diagnosis of GORD was established in more patients with the CFS 48 hour results than with the 24 hour results.
Conclusions: Despite strong correlations between oesophageal acid exposure recorded with the two devices, the Bravo CFS significantly under recorded acid exposure compared with the CPHMS. Provided some correcting factors are used, the Bravo CFS can improve the sensitivity of pHmetry for the diagnosis of GORD by allowing more prolonged recordings.
Abbreviations: GORD, gastro-oesophageal reflux disease; CFS, catheter free system; CPHMS, conventional pH measurement system; SAP, symptom analysis probability
Keywords: gastro-oesophageal reflux disease; pH monitoring; diagnosis; ambulatory recordings
Relevant Articles
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
Gut 2006 55: 434-435.
Gut 2005 54: 1672-1681.
This article has been cited by other articles:
-
Fass, R, Sifrim, D
(2009). Management of heartburn not responding to proton pump inhibitors. Gut
58: 295-309
[Abstract] [Full Text] -
Holloway, R H
(2005). Capsule pH monitoring: is wireless more?. Gut
54: 1672-1681
[Full Text]
eLetters:
Read all eLetters
- Bravo vs. catheter pH monitoring
- Mark R Fox
- Gut Online, 14 Sep 2005 [Full text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
