Gut

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
[Advanced]

Gut. Published Online First: 28 April 2008. doi:10.1136/gut.2008.151415
Copyright © 2008 BMJ Publishing Group Ltd & British Society of Gastroenterology

This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
gut.2008.151415v1
gut.2008.151415v2    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Desmond, A. N
Right arrow Articles by Shanahan, F.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Desmond, A. N
Right arrow Articles by Shanahan, F.

Paper

Crohn's disease: factors associated with exposure to high levels of diagnostic radiation

Alan N Desmond 1, Kevin O'Regan 2, Carmel Curran 1, Sebastian McWilliams 1, Tony Fitzgerald 3, Michael M Maher 2 and Fergus Shanahan 1*

1 Alimentary Pharmabiotic Centre, Department of Medicine, National University of Ireland, Cork., Republic of Ireland
2 Department of Radiology, Cork University Hospital, National University of Ireland, Cork., Republic of Ireland
3 Department of Epidemiology, National University of Ireland, Cork., Republic of Ireland

* To whom correspondence should be addressed. E-mail: f.shanahan{at}ucc.ie.

Accepted 15 April 2008


*  Abstract

Aims: Exposure to diagnostic radiation may be associated with increased risk of malignancy. The aims of this study were: (a) to examine patterns of use of imaging in Crohn's disease; (b) to quantify the cumulative effective dose (CED) of diagnostic radiation received by patients; and (c) to identify patients at greatest risk of exposure to high levels of diagnostic radiation.

Methods: 409 patients with Crohn's disease were identified at a tertiary centre. CED was calculated retrospectively from imaging performed between July 1992 and June 2007. High exposure was defined as CED>75 milli-Sieverts (mSv), an exposure level which has been reported to increase cancer mortality by 7.3%. Complete data were available for 399 patients. 45 were excluded (20 attended outside study period, 25 primarily managed at other centres).

Results: Use of computed tomography increased significantly and accounted for 77.2% of diagnostic radiation. Mean CED was 36.1mSv and exceeded 75mSv in 15.5% of patients. Factors associated with high cumulative exposure were: age<17 years at diagnosis (HR 2.1, CI 1.1-4.1), upper gastrointestinal tract disease (OR 2.4, CI 1.2-4.9), penetrating disease (OR 2.0, CI 1.0-3.9) and requirement for intravenous steroids (OR 3.7, CI 2.0-6.6); infliximab (OR 2.3, CI 1.2-4.4); or multiple (>1) surgeries (OR 2.7, CI 1.4-5.4).

Conclusions: Identifiable subsets of patients with Crohn's disease are at risk of exposure to significant amounts of diagnostic radiation. Given the background risk of neoplasia and exposure to potentially synergistic agents such as purine analogues and other immune-modulators, specialist centres should develop low-radiation imaging protocols.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2008 BMJ Publishing Group Ltd & British Society of Gastroenterology