Article Text

Download PDFPDF
Fundic accommodation assessed by SPECT scanning: comparison with the gastric barostat
  1. B D J van den Elzen1,
  2. R J Bennink2,
  3. R E Wieringa1,
  4. G N J Tytgat1,
  5. G E E Boeckxstaens1
  1. 1Departments of Gastroenterology and Hepatology, Academic Medical Centre, Amsterdam, the Netherlands
  2. 2Department of Nuclear Medicine, Academic Medical Centre, Amsterdam, the Netherlands
  1. Correspondence to:
    Dr G E Boeckxstaens
    Department of Gastroenterology and Hepatology, Academic Medical Centre, Room C2-211, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands; g.e.boeckxstaensamc.uva.nl

Abstract

Background: Recently, single photon emission computed tomography (SPECT) scanning was described as a non-invasive technique to assess fundic accommodation. However, in contrast with the barostat, no intragastric distending force is applied during SPECT scanning. We hypothesised that in the absence of a barostat balloon, SPECT scanning largely detects the volume effect of the ingested meal and is a rather insensitive tool to detect fundic relaxation.

Methods: After an overnight fast, healthy volunteers underwent a barostat study and SPECT scanning on two separate days to assess: (1) meal induced fundic accommodation (Nutridrink, 200 ml, 300 kcal); and (2) gastric relaxation to 1 mg intravenous glucagon.

Results: Fasting fundic volumes (145 (8) v 280 (32) ml; p=0.001) and average postprandial volume (329 (10) v 571 (53) ml; p=0.001) were significantly lower measured with SPECT compared with the barostat study. Meal induced fundic relaxation (183 (10) v 289 (46) ml; p=0.050) and the postprandial/fasting volume ratio (2.32 (0.10) v 2.27 (0.29); p=0.892) did not differ significantly between SPECT scanning and the barostat. However, no correlation could be determined between accommodation volumes measured by both techniques. In contrast with meal induced relaxation, the glucagon induced increase in fundic volume (19 (5) v 406 (56) ml; p=0.007) and post/pre glucagon ratio (1.16 (0.03) v 3.02 (0.54); p=0.046) were significantly lower when measured by SPECT scanning compared with the barostat.

Conclusion: SPECT scanning detects changes in postprandial volume but is less suitable than the gastric barostat in detecting changes in gastric tone. Our study therefore questions its role as a tool to detect impaired accommodation and warrants further validation of this technique.

  • Barostat
  • dyspepsia
  • gastric accommodation
  • single photon emission computed tomography
  • SPECT, single photon emission computed tomography
  • MDP, minimal distending pressure
  • VAS, visual analogue scale
  • FD, functional dyspepsia

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes