Table 4

Sensitivity, specificity, positive predictive values (PPV), and negative predictive values (NPV) for hepatic hilum to duodenal transit time (HDTT in minutes), with a sphincter of Oddi basal pressure >40 mm Hg defined as abnormal

SensitivitySpecificityPPVNPV
95% confidence limits in parentheses.
HDTT ≥913% (1–53)95% (74–100)50% (3–97)74% (53–88)
HDTT ≥825% (4–64)90% (68–98)50% (9–91)76% (54–90)
HDTT ≥725% (4–64)81% (57–94)33% (6–76)74% (51–89)
HDTT ≥638% (10–74)76% (52–91)38% (10–74)76% (52–91)
HDTT ≥563% (26–90)57% (34–77)36% (14–64)80% (51–95)