Abstract
The aim of this study was to evaluate the sensitivity and specificity of ultrasound (US) in assessing the main abdominal complications of Crohn's disease (CD), such as strictures, fistulas and abscesses. A series of 98 consecutive inpatients with complicated and uncomplicated Crohn's disease, having undergone a complete endoscopic and radiographic evaluation of the intestinal tract, entered the study. In particular, in these patients the presence of strictures, fistulas, and abscesses, detected by means of colonoscopy, small bowel x-ray, double-contrast barium enema, and computed tomography, was also assessed by means of transabdominal US. US sensitivity and specificity in the assessment of stenosis of Crohn's disease were 74.4% and 93.1%, respectively. When ileal and colonic stenosis were considered separately, transabdominal US correctly assessed 84.6% of ileal stenosis and 58.8% of colonic stenosis. Eight of 12 fistulas were detected, but only 50% of enteroenteric fistulas were diagnosed. The presence of abscesses was correctly detected in 83.3% of cases by means of US. Our data suggest that US is a suitable complementary method for the detection of abdominal complications of Crohn's disease, such as strictures and abscesses; however, its usefulness in assessing enteroenteric fistulas seems to be fairly limited.
Article PDF
Similar content being viewed by others
References
Farmer R, Hawk WA, Turnball RB: Indications for surgery in Crohn's disease: Analysis of 500 cases. Gastroenterology 71:245–250, 1976
Mekhjian HS, Switz DM, Melnyk CS, Rankin GB, Brooks RK: Clinical features and natural history of Crohn's disease. Gastroenterology 77:898–906, 1979
Sonnenberg A, Erckenbrecht J, Peter P, Niederau C: Detection of Crohn's disease by ultrasound. Gastroenterology 83:430–434, 1982
Pedersen BH, Gronvall S, Dorph S, Fahrenkrug L, Holm HH, Binder V: The value of dynamic ultrasound scanning in Crohn's disease. Scand J Gastroenterol 21:969–972, 1986
Pera A, Cammarota T, Comino E, Caldera D, Ponti V, Astegiano M, Barletti C, Rocca R, Cosimato M, Bertolusso L: Ultrasonography in the detection of Crohn's disease and in the differential diagnosis of inflammatory bowel disease. Digestion 41:180–184, 1988
Limberg B: Diagnosis of acute ulcerative colitis and colonic Crohn's disease by colonic sonography. J Clin Ultrasound 17:25–31, 1989
Limberg B, Osswald B: Diagnosis and differential diagnosis of ulcerative colitis and Crohn's disease by hydrocolonic sonography. Am J Gastroenterol 89:1051–1057, 1994
Schwerk WB, Beckh K, Raith M: A prospective evaluation of high resolution sonography in the diagnosis of inflammatory bowel disease. Eur J Gastroenterol Hepatol 4:173–182, 1992
Papi C, Iscaro D, Salvatori V, Bazuro GE, Koch MM, Capurso L: Sonographic evaluation of Crohn's disease. Ital J Gastroenterol 21:257–262, 1989
Hata J, Haruma K, Suenaga K, Yoshihara M, Yamamoto G, Tanaka S, Shimamoto T, Sumii K, Kajiyama G: Ultrasonographic assessment of inflammatory bowel disease. Am J Gastroenterol 87:443–447, 1992
Ko YT, Lim JH, Lee DH, Lee HW, Lim JW: Small bowel obstruction: sonographic evaluation. Radiology 188:649–653, 1993
Joseph AEA, Macvicar D: Ultrasound in the diagnosis of abdominal abscesses. Clin Radiol 42:154–156, 1990
Holt S, Samuel E: Grey scale ultrasound in Crohn's disease. Gut 20:590–595, 1979
Bernades P, Hecketsawailer P, Benozio M, Descos L, Geffroy Y, Hemet J: Proposition d'un systeme de criteres pour le diagnostic des enterocolites inflammatories (maladie de Crohn et rectocolite hemmoragique). Un etude cooperative du GREC. Gastroenterol Clin Biol 2:1047–1054, 1978
Di Candio G, Mosca F, Campatelli A, Bianchini M, D'Elia F, Dellagiovampaola C: Sonographic detection of postsurgical recurrence of Crohn disease. AJR 146:523–526, 1986
Dubbins PA: Ultrasound demonstration of bowel wall scan thickness in inflammatory bowel disease. Clin Radiol 35:227–231, 1984
Khaw KT, Saverymuttu SH, Joseph AEA. Correlation of 111-indium WBC scintigraphy with ultrasound in the detection and assessment of inflammatory bowel disease. Clin Radiol 42:410–413, 1990
Worlicek H, Lutz H, Heyder H, Matek W: Ultrasound findings in Crohn's disease and ulcerative colitis: A prospective study. J Clin Ultrasound 15:153–163, 1987
Joseph AEA: Ultrasound scanning. Scand J Gastroenterol 29(suppl 203):24–27, 1994
Schratter-Sehn AU, Lochs H, Handl-Zeller L, Tscholakoff D, Schratter M: Endosonographic features of the lower pelvic region in Crohn's disease. Am J Gastroenterol 88:1054–1057, 1993
Tio TL, Mulder JJ, Wijers OB, Sars PRA. Tytgat GNJ: Endosonography of peri-anal and peri-colorectal fistula and/or abscess in Crohn's disease. Gastrointest Endosc 36:331–336, 1990
Dewbury KC, Joseph AEA: Ultrasound imaging of abdominal sepsis. Scand J Gastroenterol 29(suppl 203):5–10, 1994
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Maconi, G., Bollani, S. & Bianchi Porro, G. Ultrasonographic detection of intestinal complications in Crohn's disease. Digest Dis Sci 41, 1643–1648 (1996). https://doi.org/10.1007/BF02087914
Received:
Revised:
Accepted:
Issue Date: