Elsevier

Clinica Chimica Acta

Volume 205, Issues 1–2, 31 January 1992, Pages 51-64
Clinica Chimica Acta

Limitations of the triolein breath test

https://doi.org/10.1016/0009-8981(92)90353-RGet rights and content

Summary

Patients being investigated for intestinal absorptive capacity were classified as normals or malabsorbers on the basis of three fat absorption tests. Malabsorbers were further classified as mild, moderate, severe or gross according to severity of malabsorption. Using this classification system the triolein breath test was evaluated in 53 patients. Seventeen patients were excluded because their graph of percentage breath [14C]carbon dioxide versus time was exponential indicating that the peak [14C]-carbon dioxide may be occuring later than the six hour duration of the test. The sensitivity and specificity of the triolein breath test were found to be 100% and 96%, respectively and moderate correlations with the individual fat absorption tests were found. However, the breath test was limited in its capacity to predict the severity of malabsorption. Carbon dioxide output was also measured in order to determine the applicability of using an assumed value. The respiratory quotient and variability of results were high in nineteen patients indicating possible hyperventilation. In 32 patients with reproducible results and normal respiratory quotients the average carbon dioxide output was 8.66 mmol/kg per hour with a wide range of 5–12.4mmol/kg per hour. Consequently the use of an assumed carbon dioxide output can introduce considerable errors in the triolein breath test. This study highlights drawbacks of the triolein breath test, particularly problems in using an assumed carbon dioxide output for its calculation, its inability to predict the severity of malabsorption and the nature of the dietary load used.

References (24)

  • BeninoL. et al.

    Is the14C-triolein test useful in the assessment of malabsorption in clinical practice?

    Digestion

    (1984)
  • PedersenN.T. et al.

    Estimation of [14C]triolein assimilation as a test of lipid assimilation. Breath test or measurement of serum radioactivity

    Scand J Gastroenterol

    (1982)
  • Cited by (20)

    • A novel method to identify fat malabsorption: The Serum Retinyl Palmitate Test

      2015, Clinica Chimica Acta
      Citation Excerpt :

      Breath tests for fat malabsorption were hypothesized to offer a reliable alternative to stool tests. 14C-triolein absorption has been used as an alternative to fecal fat; assessing both lipolysis and absorption [11]. However, results vary especially in patients with underlying metabolic concerns and have difficulty distinguishing degrees of malabsorption [12].

    • Diagnosing small bowel malabsorption: A review

      2014, Internal and Emergency Medicine
    • Approach to the Patient with Diarrhea

      2009, Principles of Clinical Gastroenterology
    View all citing articles on Scopus
    View full text