Endoscopy 2000; 32(6): 457-460
DOI: 10.1055/s-2000-652
Original Article
Georg Thieme Verlag Stuttgart ·New York

The Use of Inhaled Nitrous Oxide for Flexible Sigmoidoscopy: A Placebo-Controlled Trial

T. A. Harding, J. A. Gibson
  • Staffordshire General Hospital, Stafford, UK
Further Information

Publication History

Publication Date:
31 December 2000 (online)

Background and Study Aims: Flexible sigmoidoscopy is a widely used diagnostic technique which is increasingly being adopted as part of bowel cancer screening programmes. It is conventionally performed without sedation or analgesia, but significant numbers of patients experience mild to moderate discomfort during the procedure. The aim of this study was to assess the usefulness of self-administered nitrous oxide to reduce discomfort during flexible sigmoidoscopy, which may have an effect of improving compliance.

Patients and Methods: In a double-blind, randomized, placebo-controlled study, 87 patients were enrolled. Of these, 45 received nitrous oxide/oxygen (50 % mix) to inhale during the procedure and 42 received oxygen alone. The patients recorded their opinions on the efficacy of the agent in a questionnaire after the examination. The endoscopist recorded the success of the procedure.

Results: The groups were well matched for age and sex. Significant reductions in levels of discomfort and increased levels of agreement to undergo the procedure again were noted for the actively treated group (P < 0.05). No significant differences in side effects or success of the procedure were observed.

Conclusions: The addition of self-administered nitrous oxide offered significant benefits in the area of patient discomfort during flexible sigmoidoscopy. The availability of this agent is useful in clinical practice and may enhance compliance with a screening programme.

References

  • 1 Levin B T, Rothenberger D, Dodd G D, Smith R A. The American Cancer Society guidelines for colorectal cancer screening: have we gone too far (or not far enough)?.  Gastroenterology. 1998;  114 1341-1343
  • 2 Cockburn J, Thomas R JS, McLaughlin S J, Reading D. Acceptance of screening for colorectal cancer by flexible sigmoidoscopy.  J Med Screen. 1995;  2 79-83
  • 3 McCarthy B D, Moskowitz M A. Screening flexible sigmoidoscopy: patient attitudes and compliance.  J Gen Int Med. 1993;  8 120-125
  • 4 Lindblom A, Jansson O, Jeppsson B, et al. Nitrous oxide for colonoscopy discomfort: a randomised double-blind study.  Endoscopy. 1994;  26 283-286
  • 5 Saunders B P, Fukumoto M, Halligan S, et al. Patient administered nitrous oxide/oxigen inhalation provides effective sedation and analgesia for colonoscopy.  Gastrointest Endosc. 1994;  40 418-421
  • 6 Trojan J, Saunders B P, Woloshynowych M, et al. Immediate recovery of psychomotor function after patient administered nitrous oxide/oxygen inhalation for colonoscopy.  Endoscopy. 1997;  29 17-22
  • 7 Fich A, Efrat R, Sperber A, et al. Nitrous oxide inhalation as sedation for flexible sigmoidoscopy.  Gastrointest Endosc. 1997;  45 10-12
  • 8 Saunders B P, Elsby B, Boswell A M, et al. Intravenous antisplasmodic and patient-controlled analgesia are of benefit for screening flexible sigmoidoscopy.  Gastrointest Endosc. 1995;  42 123-127
  • 9 Atkin W S, Cuzick J, Northover J MA, Whynes D K. Prevention of colorectal cancer by once only sigmoidoscopy.  Lancet. 1993;  341 736-740
  • 10 Baskett P JF, Eltringham R J, Bennett J A. An assessment of the oxygen tensions obtained with pre-mixed 50% nitrous oxide and oxygen mixture used for pain relief.  Anaesthesia. 1973;  28 449-450

T. A. Harding, M.D.

Dept. of Gastroenterology (c/o Dr ET Swarbrick sec) New Cross Hospital

Wednesfield Road Wolverhampton WV10 0PQ United Kingdom

Fax: Fax:+ 44-1902-643027

Email: E-mail:timh@shrewsbury97.freeserve.co.uk

    >