The 13C urea breath test in the diagnosis ofHelicobacter pylori infection
  1. V Savarinoa,
  2. S Vignerib,
  3. G Cellea
  1. aDipartimento di Medicina Interna e Specialità Mediche, Cattedra di Gastroenterologia, Università di Genova, Italy, bIstituto di Medicina Interna e Geriatria, Università di Palermo, Italy
  1. Professor V Savarino, Dipartimento di Medicina Interna e Specialità Mediche, Cattedra di Gastroenterologia, Università di Genova, Viale Benedetto XV, n. 6, 16132 Genova, Italy.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Summary

The urea breath test (UBT) is one of the most important non-invasive methods for detecting Helicobacter pylori infection. The test exploits the hydrolysis of orally administered urea by the enzyme urease, which H pylori produces in large quantities. Urea is hydrolysed to ammonia and carbon dioxide, which diffuses into the blood and is excreted by the lungs. Isotopically labelled CO2 can be detected in breath using various methods.

Labelling urea with 13C is becoming increasingly popular because this non-radioactive isotope is innocuous and can be safely used in children and women of childbearing age. Breath samples can also be sent by post or courier to remote analysis centres. The test is easy to perform and can be repeated as often as required in the same patient. A meal must be given to increase the contact time between the tracer and the H pylori urease inside the stomach. The test has been simplified to the point that two breath samples collected before and 30 minutes after the ingestion of urea in a liquid form suffice to provide reliable diagnostic information. The cost of producing 13C-urea is high, but it may be possible to reduce the dosage further by administering it in capsule form.

An isotope ratio mass spectrometer (IRMS) is generally used to measure13C enrichment in breath samples, but this machine is expensive. In order to reduce this cost, new and cheaper equipment based on non-dispersive, isotope selective, infrared spectroscopy (NDIRS) and laser assisted ratio analysis (LARA) have recently been developed. These are valid alternatives to IRMS although they cannot process the same large number of breath samples simultaneously.

These promising advances will certainly promote the wider use of the13C-UBT, which is especially useful for epidemiological studies in children and adults, for screening patients …