New-generation chromoendoscopy may increase confidence in the DISCARD2 study
  1. Osamu Toyoshima1,
  2. Keisuke Hata1,2,
  3. Shuntaro Yoshida1,3,
  4. Masahide Arita1
  1. 1 Department of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan
  2. 2 Department of Surgical Oncology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
  3. 3 Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
  1. Correspondence to Dr Osamu Toyoshima, Department of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, 157-0066, Japan; t{at}ichou.com

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

We read with interest the article by Rees et al, which assessed narrow band imaging (NBI) optical diagnosis of small colorectal polyps in routine clinical practice (the DISCARD2 study).1 Several modalities can potentially be used for screening colonoscopy. The quality of white light endoscopy (WL) has greatly improved after the advent of high-definition endoscopy. Chromoendoscopy (CE) with indigo carmine is one of the traditional dye spraying methods for clearer visualisation of subtle lesions. Image-enhanced endoscopy is also becoming popular, and the new NBI system has improved brightness and contrast relative to those of the first-generation systems.

The study by Rees et al did not show the usefulness of NBI in a multicentre routine (non-specialist) clinical practice for differentiating adenoma from non-adenomatous lesions and concluded that routine use of NBI was not recommended outside of specialist centres. This is an important message because many randomised control trials are conducted in academic centres by experienced staff.

We have been routinely performing trimodal observation (ie, WL, NBI and CE) from the caecum to the hepatic flexure to minimise missed polyp rates by using Olympus Elite processors and 290 series endoscopes in daily clinical practice. Initially, we performed WL followed by NBI and CE. We additionally performed an alternative observation method by performing NBI followed by WL and CE. We retrospectively analysed these two non-randomised methods (table 1). The adenoma detection rate of the caecum to the ascending colon was significantly higher in the WL first group than in the NBI first group (10% vs 6.1%, respectively; p=0.048), whereas the second and third cumulative detection rates were comparable between the two groups (second detection rates: 12% vs 11%, p=0.50; third detection rates: 18% vs 19%, p=0.85). Additionally, we detected many adenomas in the last observation by CE, with miss rates of 43% and 44%.

Table 1

Comparison of adenoma detection rates and miss rates of caecum to ascending colon between white light first and NBI first group

The second-generation NBI provided brighter images than those of the previous system and yielded a higher adenoma detection rate than that of the WL examination.2 However, our investigation showed a higher adenoma detection rate for WL than for NBI. Several points should be considered when interpreting the results. First, because the proximal colon has a wide lumen and large haustra, the NBI brightness might not be sufficient for observation, whereas the brightness is sufficient for the inspection of the oesophagus where the lumen is narrow and straight.3 Second, we think that the NBI visibility depends on the bowel preparation status compared with WL, which is important in some populations because, for example, many Japanese have diverticula in the proximal colon caused by poor preparation.4 5 Third, small polyps with flat or depressed morphology are more common in the proximal colon than in the distal colon. These are possibly more easily obscured by residual faeces and are more likely to be missed during NBI observation.4

The tandem crossover trimodal methods provided similar second cumulative rates, which indicate that they compensate for each other’s shortcomings. The adenoma detection rate in the last CE examination was high. A study in which the adenoma detection rate was found to be higher in CE than in WL using the previous-generation system suggests that the same tendencies apply to the new-generation system.6 In each of the three modalities, the type of modality that best detects a particular type of lesion should be estimated.

It would be interesting to see if optical diagnosis using multiple modalities, including not only NBI but also CE, improve the confidence in the DISCARD2 study.

References

Footnotes

  • Contributors All authors: designed the study. OT: analysed and summarised the results. OT and KH: wrote the manuscript.

  • Funding OT and SY received personal fees from Olympus Corporation, outside the submitted work.

  • Competing interests None declared.

  • Ethics approval Ethical Review Committee of Hattori Clinic.

  • Provenance and peer review Not commissioned; internally peer reviewed.