Elsevier

Clinical Radiology

Volume 56, Issue 3, March 2001, Pages 225-230
Clinical Radiology

Regular Article
Transabdominal Ultrasonography of the Small Bowel After Oral Administration of a Non-absorbable Anechoic Solution: Comparison with Barium Enteroclysis

https://doi.org/10.1053/crad.2000.0625Get rights and content

Abstract

AIM: The aim of this study was to determine if oral administration of a non-absorbable anechoic solution conveys any benefit during abdominal ultrasound (US), with special reference to its accuracy.

MATERIALS AND METHODS: Fifty-three adult out-patients scheduled for small bowel barium enema (SBE) were included. The day before SBE all patients underwent abdominal US before and after oral administration of an isotonic non-absorbable electrolyte solution containing polyethylene glycol (PEG-ELS). Sensitivity and specificity were evaluated using SBE as a gold standard.

RESULTS: After ingestion of PEG-ELS satisfactory distension of the intestinal lumen was obtained (11–25 mm) with sequential visualization of jejunoileal loops in 30.9 ± 17.3 min. In 15 out of 53 cases both US and SBE showed bowel changes characteristic of Crohn's disease. In three out of 53 cases both US and SBE showed neoplasms. In one out of 53 cases US was negative, SBE positive for local nodularity and ulcerations typical of Crohn's disease. In one out of 53 cases US was negative, SBE positive for macronodularity consistent with coeliac disease. In five out of 53 cases US was negative, while SBE was positive for mininodularity expressive of lymphoid hyperplasia. In 28 out of 53 cases both examinations were negative.

CONCLUSION: PEG-ELS administration allows a thorough US investigation of the small bowel, with fair sensitivity (72%) and excellent specificity (100%). False negative findings are mainly due to lymphoid hyperplasia, a feature of uncertain significance in adults. Cittadini G.et al.(2001). Clinical Radiology56, 225–230.

References (27)

  • RF Thoeni et al.

    Enteroclysis and small bowel series: comparison of radiation dose and examination time

    Radiology

    (1991)
  • GA Rollandi et al.

    Spiral CT of the abdomen after distention of small bowel loops with transparent enema in patients with Crohn's disease

    Abdom Imaging

    (1999)
  • HK Ha et al.

    Application of MRI for small intestinal diseases

    J Magn Reson Imaging

    (1998)
  • Cited by (29)

    • Contrast-enhanced ultrasound in the diagnosis of patients suspected of having active Crohn's disease: Meta-analysis

      2015, Ultrasound in Medicine and Biology
      Citation Excerpt :

      Recent reports suggest that the use of contrast agent is more suitable for evaluation of the microvasculature because of its increased sensitivity in detecting signals produced by contrast media (Heyne et al. 2002; Neye et al. 2004). This has led to a significant advance in precise evaluation of intestinal wall vasculature and has been found to be a sensitive tool for estimating inflammatory activity in CD reflected by parietal hypervascularization status (Cittadini et al. 2001; Pallotta et al. 2012; Parente et al. 2002; Toth 1976). What's more, conventional bowel US detects mainly bowel wall thickening, whereas the recently available oral isotonic, non-absorbable solutions are able to enlarge the collapsed bowel, which is more favorable in the detection of focal wall thickness because it enables better visualization of the narrowed tract (Di Sabatino et al. 2002).

    • Diagnostic imaging in the diagnosis of small bowel Crohn's Disease - A literature review

      2008, Radiography
      Citation Excerpt :

      If this is the case, the most valid studies are those completed by Parente et al.17–20 Cittadini et al. suggest that one drawback to using ultrasound, as a diagnostic tool for Crohn's Disease is the insufficient visualisation of the intestinal lumen due to luminal collapse.25 However, they suggest that adding an oral non-absorbent isotonic anechoic electrolyte as a contrast agent can increase the sensitivity from 72% to 100%.25

    • Ultrasound in inflammatory bowel disease

      2017, Crohn's Disease and Ulcerative Colitis: From Epidemiology and Immunobiology to a Rational Diagnostic and Therapeutic Approach: Second Edition
    View all citing articles on Scopus
    f1

    Author for correspondence and guarantor of study: Prof. G. Cittadini, Istituto di Radiologia Università, Largo R. Benzi 10, 16132 Genova, Italy. Tel: +39 10 352178; Fax: +39 10 354053; E-mail: [email protected]

    View full text