Reproducibility and reliability of the 13C-acetate breath test to measure gastric emptying of liquid meal in infants

Nutrition. 2005 Mar;21(3):289-94. doi: 10.1016/j.nut.2004.05.027.

Abstract

Objective: This study assessed the noninvasive 13C-acetate breath test (13C-ABT) as a reliable and reproducible method to evaluate gastric emptying in infants

Methods: Gastric emptying was measured simultaneously by scintigraphy and 13C-ABT in 11 infants with clinical symptoms of gastroesophageal reflux to validate the method compared with the gold standard. Gastric emptying was also measured with 13C-ABT in a separate group of 14 healthy infants on 2 consecutive days to evaluate reproducibility of the method. Half-emptying times obtained with scintigraphy and 13C-ABT were correlated with Pearson's analysis. The variability of the half-emptying times obtained on 2 consecutive days was analyzed with paired t test and by the coefficient of variation as proposed by Bland and Altman.

Results: The mean emptying times obtained with scintigraphy and 13C-ABT were not different (89 +/- 27 min and 70 +/- 39 min, respectively, P = 0.22). Both methods correlated significantly (r = 0.75, P < 0.05). Half-emptying times measured on 2 consecutive days with 13C-ABT were 69 +/- 31 min and 68 +/- 30 min, respectively (mean difference = 1.4 +/- 12.4 min, P = 0.67). Intraindividual coefficient of variation was 6.3%.

Conclusions: This study supports the 13C-ABT method as a useful tool to evaluate gastric emptying of liquids in healthy infants and in infants with gastroesophageal reflux in the field of research and in clinical evaluations.

Publication types

  • Validation Study

MeSH terms

  • Acetates
  • Breath Tests / methods
  • Carbon Isotopes
  • Female
  • Gastric Emptying / physiology*
  • Gastroesophageal Reflux / physiopathology
  • Humans
  • Infant
  • Infant Food*
  • Male
  • Radionuclide Imaging / methods
  • Reference Values
  • Reproducibility of Results
  • Time Factors

Substances

  • Acetates
  • Carbon Isotopes